GHD Glide Hot Brush Cable Replacement
This the GHD Glide heated brush.
It can not be repaired but the mains cable can be changed if damaged.
The chrome GHD metal end ring needs to be removed first.
Slide a thin but strong metal tool into the gap between the plastic arm and metal end ring. Try and use the blade at about 45 degs.
Gently prise it off as shown below.
Move the end ring clear of the screws.
With the screws removed simply carefully separate the two halfs just enough to pull the mains cable out of the socket.
Fit the new cable and reverse the process.
The cable can be purchased from our shop. GHD Glide Mains Cable.